By Lenny Filipkowski, Product Manager, Industrial Components, AutomationDirect

Many machines and robots require safety circuits to stop all or part of operation in the event of an emergency. Safety circuits are also used to keep all or part of a machine or robot from running while there is human activity in close proximity, either for normal operations or maintenance.

These safety circuits are typically configured using safety relays, or a safety-rated PLC or other safety-rated controller. But in many cases, multi-function safety relays are a better option (Figure 1). A multi-function safety relay is a configurable device with multiple inputs and outputs. It’s more powerful than a single-function safety relay, and less complex and expensive than a safety-rated PLC.

One or more multi-function safety relays can often be used to replace many basic single-function safety relays, simplifying installations and saving money. In other cases, multi-function safety relays can be used instead of a safety-rated PLC, resulting in substantial savings while streamlining implementation and maintenance.

Relays limit options

Multi_Safety_2.JPG

Machine and robot builder OEMs, and end users with similar applications, often have to monitor and control many I/O points that include a relatively small number of I/O points performing safety-related functions.

The most common safety circuit for simple machines with up to three safety inputs (such as an E-stop and two gate switches) is a basic single-function safety relay that has redundant contacts and is self-monitoring. As a machine or robot’s safety system requires more safety inputs, an option is to keep adding basic single-function safety relays, or to possibly go to a much more expensive safety-rated PLC.

Adding basic single-function safety relays to monitor and control the safety I/O often results in overly complex installations involving a relatively large number of relays. If zone control is desired, which requires certain parts of the machine or robot to continue operation for particular types of events, then the number of required safety relays can rapidly multiply, and complexity can grow exponentially.

When many relays are used, troubleshooting can be very difficult as each connection point and component need to be examined to determine the point of failure. Modifications are very difficult to implement as they require rewiring and often the addition of more relays.

In installations with four or more safety I/O points, one or two multi-function relays can often be used to replace four or more basic single-function safety relays, simplifying installations and saving money.

Multi_Safety_3.JPGThe benefits of this approach are listed in Table 1 and described below. Because fewer relays are required, less panel space is needed along with much less wiring. This cuts panel footprint and saves on upfront labor costs.

If changes are required to accommodate modifications to the machine or robot, or to add features, it’s much easier to reconfigure a multi-function safety relay, as opposed to adding more basic single-function safety relays.

Multi-function safety relays are available in a number of styles, including, but not limited to, dual channel monitoring with or without time delay, two-hand control, light curtain monitoring, speed monitoring, motor standstill monitoring, and relay extension to increase the number of output contacts.

These relays come in a wide offering of input and output configurations. A simple base unit can handle a variety of inputs, and expandable input and output modules can be added as needed. Multi-function relays do not need software for configuration or operation, so setup and maintenance is typically very straightforward and simple.

One specific type of multi-function safety relay allows desired functions to be set via a rotational switch at the front of the relay. It is designed to handle a variety of inputs such as E-stops, gate switches, light curtains and/or two-hand buttons—with appropriate outputs to trigger alerts and specific machine or robot operations.

Another type of multi-function relay provides more power through a combination of rotary and DIP switches that are used for initial configuration. This relay type typically can accommodate a much higher number of I/O, up to 24 inputs and 24 outputs, by utilizing separate input and output modules.

Multi_Safety_4.JPG

A system with an E-stop and two safety light curtains would require three single-function safety relays. Figure 2 shows the same system with a safety circuit consisting of just one multi-function relay, greatly simplifying the circuit while cutting costs and adding flexibility.

Simpler than a PLC

For zone control and other complex safety circuits, another solution is to use a safety-rated PLC to control and monitor just the safety I/O, or even all of the I/O, but this can be very expensive and can add unnecessary complexity.

Adding a separate safety-rated PLC in addition to the main controller requires the OEM to purchase, program and maintain a second programmable system in addition to the main controller. This safety-rated PLC will need its own programming software, with consequent renewal fees. The learning curve for a safety-rated PLC can be steep, and costs are relatively high.

Alternatively, one safety-rated PLC can be used to perform all required control and safety functions. This eliminates the problem of two separate systems, but it increases costs significantly, and generally only makes sense when a very large percentage of the machine or robot I/O is directly related to safety.

Multi_Safety_5.JPG

One or more multi-function relays can often be used to perform all safety-related functions for a machine or robot, resulting in substantial savings while simplifying implementation and maintenance as compared to a safety-rated PLC. The benefits of this solution are listed in Table 2 and described in detail below.

It’s typically much easier to configure a multi-function safety relay than it is to program a safety-rated PLC. There’s no need to purchase, update and maintain programming software, and a programming PC isn’t required.

A multi-function safety relay is easily integrated into the main control system by simply hard-wiring a few I/O points between the relay and the controller.

Because a multi-function safety relay is much less expensive than a safety-rated PLC, it often can be used to cost-effectively handle all of the safety-related I/O, obviating the need to upgrade the main controller to one that’s safety-rated.

Caveats and considerations

Very simple applications are often best served by one or two single-function safety relays and don’t require the added expense of multi-function relays. A machine, robot or other system that may only have an E-stop along with a set of light curtains or door switches is an example of an application where a single-function safety relay would be the best choice.

Multi-function relays do have their limitations and can only be expanded to a certain practical limit in terms of the total number of I/O points and complexity of function. Cost and particularly complexity can increase to a point where it makes sense to use a safety-rated PLC.

Very complex applications with many safety I/O points and multiple zone control, or applications with requirements that change substantially from machine to machine or over time, may be better served by using a safety-rated PLC, either for just the safety I/O or for all of the I/O.

Multi-function relays result in savings

Multi_Safety_6.JPG

A manufacturer of limit switches upgraded to a multi-function safety relay system for its production cell to accommodate increased automation of the processes used in the construction of its products (Figure 3).

The original safety circuit design was mostly manual, and thus required substantial operator interaction. The circuit had an E-stop, one set of safety light curtains, and door switches.

The newer automated production system required the addition of light curtain, door switches and safety mats at different locations within the production process. Different interlocking requirements such as speed monitoring of some of the equipment were also needed.

By automating the production process, the manufacturer was able to relocate eight employees to different functions in the company, and to increase production by 40%.

By switching to a multi-function safety relay instead of adding more single-function safety relays, the company saved 30% of the initial cost, and gained a much more flexible safety system.

The manufacturer did look at adding a safety-rated PLC, but the cost would have been more than 60% higher than the multi-function relay system, and the complexity of having to support such a system was not justifiable.

Conclusion

Machines and robots with just a couple of basic safety inputs such as an E-stop and one or two door switches or other safety-related inputs are typically best served by a safety system with one or two single-function safety relays.

When a machine has many I/O points, with a high proportion safety-related, a safety-rated PLC is often the best fit.

But for a machine or robot in between these two extremes, an easy to configure and inexpensive safety system using multi-function relays may be the preferred choice.

Source

AutomationDirect_Link_Logo.JPG

Multi_Safety_7.JPG

Changing Scene

  • Prev
Schneider Electric is introducing a personalized digital experience for logged in customers ...
Littelfuse, Inc., an industrial technology manufacturing company empowering a sustainable, ...
The international FRABA Group has announced the creation of two new business units: UBITO and ...
Recently, EY Canada welcomed SuMO IT Solutions — an enterprise service and operations management ...
Recently, Siemens Mobility was pleased to announce that it is acquiring RailTerm, a Canadian based ...
ATS Automation Tooling Systems Inc., a major automation solutions provider, recently announced the ...
Recently, Phoenix Contact Canada Ltd. was proud to announce and welcome Robert Kostash, P. Eng., as ...
The technology enables rapid prototyping of vehicle tires through precise laser material ...
Lakeside was recently excited to announce the opening of a new service center and office located at ...
EPLAN offers a variety of training courses to help you further your knowledge and make you a better ...


ATS Acquires Industrial Automation System Integrator CIM

Conrad OakeyNovaTech, a medium-sized provider of automation and engineering solutions serving electric utilities and process manufacturing industries for 40 years, recently announced the appointment of Conrad Oakey as their Chief Executive Officer.


Oakey, who originally joined NovaTech in 2000, includes among his many accomplishments consolidating the management of the two business units (power and process automation), simplifying online ordering and customer support, as well as continuing to improve the functionality and ease-of-implementation of the company’s three product lines.

Read More


 

The Automated Future of Material Removal

The Automated Future of Material RemovalAutomating a deburring or surface finishing application is a smart, responsible, and effective way to improve a manufacturing process. There is a serious need for the automation of manual material removal and deburring tasks to help improve employees’ health, combat manufacturing labor shortages, and increase product consistency and quality.

The historical roadblocks for automated material removal are melting away as return on investment gets faster, more integrators and manufacturers cultivate hands-on experience, and technology advances to make processes easier.

Read More


When To Use Multi-Function Safety Relays

Multi-Function Safety RelaysBy Lenny Filipkowski, Product Manager, Industrial Components, AutomationDirect

Many machines and robots require safety circuits to stop all or part of operation in the event of an emergency. Safety circuits are also used to keep all or part of a machine or robot from running while there is human activity in close proximity, either for normal operations or maintenance.

These safety circuits are typically configured using safety relays, or a safety-rated PLC or other safety-rated controller. But in many cases, multi-function safety relays are a better option (Figure 1). A multi-function safety relay is a configurable device with multiple inputs and outputs.

Read More

 


 

Williams Advanced Engineering, Aerofoil Energy and Inovo Join Forces on New Robotic Test Programme to Improve Supermarket Fridge Efficiency

Williams Advanced EngineeringWilliams Advanced Engineering (WAE), Aerofoil Energy and Inovo Robotics are working together on an innovative new R&D programme that uses robots to further improve the energy efficiency of supermarket fridges.

Based at WAE’s site in Grove, Oxfordshire, the pioneering new initiative sees Inovo’s collaborative robots – called ‘cobots’ – repeatedly opening and closing the doors of test fridges to emulate real-world supermarket trading conditions. These fridges feature the revolutionary F1-inspired Aerofoil shelf edge technology along with Aerofoil Energy’s new “Vortex” energy efficient fridge technologies.

 

Read More


 

Product News

  • Prev
B&R has added three new option boards for its X90 product line. With the new boards, it is now ...
Machine designers can save time and costs, optimize machine performance, and get to market faster ...
Sealcon has many unique cable glands but maybe none more unique than the BXA/BXI fitting. Why ...
With the TERMITRAB complete product family from Phoenix Contact, they provide you with the ...
The STEP POWER power supply family from Phoenix Contact has been extended to include new devices ...
The LEMO B Series offers a modular, ergonomic, rugged and reliable circular multipole connector for ...
Moxa Inc., a provider in industrial communications and networking with a focus on securing ...
The PTVME test-disconnect terminal blocks from Phoenix Contact are an extension to the PTV ...
Introducing the Type 4 4X mild steel and stainless steel consolet series, which serves as an ...
With a new bus controller, B&R has added a gate measurement module to its portfolio for ...
Kerrwil Publications Great Place to Work. Certified December 2019 - December 2020

538 Elizabeth Street, Midland,Ontario, Canada L4R2A3 +1 705 527 7666
©2021 All rights reserved

Use of this Site constitutes acceptance of our Privacy Policy (effective 1.1.2016)
The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Kerrwil